Model
|
Description
|
Test Pulse
Voltage Amplitude
|
Test Pulse
Waveform
|
Max. Stored Energy
|
|
IPG 255
|
Surge testing of electrical insulation acc. to IEC 255
|
0.8, 1, 1.5, 2.5, 4, 5, 6 & 8 kV
|
1.2/50 µs
|
0.5 J
|
|
IPG 1201
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps - as per EN 60065
|
12 kV
|
EN 60065
|
0.072 J
|
|
IPG 605
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps
|
6.25 kV
|
1.2/50 µs
|
5 J
|
|
IPG 1012
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps
|
10 kV
|
1.2/50 µs
|
12 J
|
|
IPG 1218
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps
|
12 kV
|
1.2/50 µs
|
18 J
|
|
IPG 2025
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps
|
20 kV
|
1.2/50 µs
|
25 J
|
|
IPG 2436
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps
|
24 kV
|
1.2/50 µs
|
36 J
|
|
IPG 620
|
High-voltage Pulse Generator for simulating surges caused by switching of inductive loads, power system switching, lightning strokes acc. to CCITT - K22
|
6 kV
|
1.2/50 µs
|
20 J
|
|
IPG 1050
|
High-voltage Pulse Generator for simulating surges caused by switching of inductive loads, power system switching, lightning strokes acc. to CCITT - K22
|
10 kV
|
1.2/50 µs
|
50 J
|
|
PG 100-500
|
High-voltage Pulse Generator
|
100 kV
|
1.2/50 µs
|
500 J
|
|
PG 140-1000
|
High-voltage Pulse Generator
|
140 kV
|
1.2/50 µs
|
1,000 J
|
|
PG 4-641
|
High-voltage Pulse Generator
|
Open circuit voltage:
10/160 µs
|
3.6 kV
|
600 J
|
|
Short circuit current:
10/160 µs
|
480 Ap
|
||||
IPG 602
|
Pulse current generator
|
6 kV
|
1.2/50 µs
|
2 J
|
|
IPG 1012s
|
High-voltage Pulse Generator for testing impulse dielectric strength of components, insulation, air- and surface flash-over gaps. Inc. current sense facility to detect flashover.
|
10 kV
|
1.2/50 µs
|
12 J
|
|
IPG 809
|
High-voltage Pulse Generator for dielectric testing of X- and Y-capacitors with standard impulse voltages 1.2/50 µs up to 8 kV acc. to IEC 384-14 & EN 132400
|
8 kV
Cx-range: 0.1-27 nF
|
1.2/50 µs
|
9 J
|
|
PG 6-401
|
High-voltage Pulse Generator for dielectric testing of X- and Y-capacitors with standard impulse voltages 1.2/50 µs up to 6 kV acc. to IEC 384-14 & EN 132400
|
10 kA
Cx-range: 33-470 nF
|
1.2/50 µs
|
400 J
|