Model
Generator Description
Test Pulse
Amplitude
Test Pulse
Waveform
Max. Stored Energy

IPG 506
Front Chopped Wave generator, as per CCITT/ITU-T, K12, to  measure gas discharge tube spark-over voltage
Impulse voltage 5 kV: dv/dt = 100 V/µs to 5000 V/µs

DC-voltage 637 V: dv/dt = 100 V/s

6 J
PG 6-200
Surge current generator
5 kA
8/20 µs
200 J
PG 6-400
Surge current generator
10 kA
8/20 µs
400 J
EMC 2004
Pulse Generator System

Mainframe plus plug-in Pulse Forming Networks
Pulse current plug-in's:
20 kA
8/20 µs
1,500 J
5 kA
10/50 µs
1,500 J
600 A
10/350 µs
1,500 J
300 A
10/700 µs
1,500 J
200 A
10/1000 µs
1,500 J
PG 10-1520
Surge current generator
2 x 10 kA
8/20 µs
1,500 J
PG 6-2402
Surge current generator
2 x 25 kA
8/20 µs
2,400 J

PG 6-432
Impulse Life Test generator
2 x 100 A
10/100 µs
360 J
2 x 100 A
10/1000 µs
360 J
HVTG 2/10

High Voltage Test Unit. as per CCITT, 12 TR 1, K17
Open circuit
voltage:
2 kVrms
Short circuit
current:
10 Arms
Test interval:
continuous or 0-999 cycles

PG 2-750
Surge current generator, as per
FCC, part 68, ANSI/TIA 968-A-2002
4 x 100 A
(1,600 V)
10/160 µs

2 x 100 A
(800 V)
10/560 µs
Option 2 for GR-1089-CORE:
2 x 100 A
(1,000 V)
10/1000 µs
PG 6-500
Surge current generator, as per GR-1089-CORE
500 A / 4-wire
(± 2,500 V)
2/10 µs

500 A / 4-wire
(± 5,000 V)
2/10 µs
100 A / 4-wire
(± 800 V)
2/10 µs
100 A / 4-wire
(± 1,500 V)
2/10 µs
IPG 620
High-voltage pulse generator, as per CCITT 12 TR 1, K17
6 kV
1.2/50 µs
20 J
IPG 1050
High-voltage pulse generator, as per CCITT 12 TR 1, K17
10 kV
1.2/50 µs
50 J
PG 10-700
High-voltage pulse generator, as per CCITT 12 TR 1, K17
4.5 kV
1.2/50 µs
10 J
4.5 kV
10/700 µs
200 J
PG 6-364
High-voltage pulse generator, as per CCITT 12 TR 1, K17 & K20
6 kV
1.2/50 µs
10 J
6 kV
10/700 µs
360 J
One additional waveform may be selected from: 100/700µs, 0.5/700µs or 1/1000µs
PG 10-1000
High-voltage pulse generator, as per CCITT 12 TR 1, K17 & K20
10 kV
1.2/50 µs
50 J
10 kV
10/700 µs
1,000 J
PG 12-1440
High-voltage pulse generator, as per CCITT 12 TR 1, K17 & K20
12 kV
1.2/50 µs
72 J
12 kV
10/700 µs
1,440 J
PG 14-1960
High-voltage pulse generator, as per CCITT 12 TR 1, K17 & K20
14 kV
10/700 µs
2,000 J
PG 20-4000
High-voltage pulse generator, as per  CCITT 12 TR 1 / ITU-T Spec. K17 & K20
20 kV
10/700 µs
4,000 J
PG 4-641
High-voltage pulse generator, as per ITU-T Spec. K20
4 kV
10/700 µs
640 J
PIG 1500
Power Induction generator, as per CCITT 12 TR 1, K20
Open circuit output voltage:
20 - 1,500 Vrms
Test-time:
0.1 - 2.5 sec.
Coupling impedance:
100 ohm //(0.5µF or 1.0µF)






Coupling/De-coupling Networks






KN100-4
4 x 100 Ohm decoupling resistors, as specified in CCITT 12 TR1, K17 & K20


CDN 5-64
64-outputs
Max. test voltage:
5 kV
10/700 µs
Designed for coupling to ISDN-Ports, output is selectable 1 of 64
CDN 5-80
80-outputs
Max. test voltage:
5 kV
10/700 µs
Designed for coupling to ISDN-Ports, output is selectable 20 of 80
Range Overview
.......................................................................................................................................................................
Telecom Test Generators (CCITT / ITU)
......................................................................................................................................................
All products on this page are manufactured by HILO-TEST GmbH, an ISO 9001 accredited company.

HILO-Test, established more than 25-years, is a major European-based manufacturer of Surge & Impulse generator systems.
EMC 2004 Pulse Generator System - A flexible component test generator system meeting the requirements of many CCITT/ITU-T specifications.
The EMC 2004 Pulse Generator System is a flexible component test generator system. It comprises a mainframe in to which a wide-range of Pulse Forming Networks can be plugged. The mainframe houses the 10 kV power supply and 30 µF energy storage capacitor. The maximum stored energy of the EMC 2004 system is 1500 Joules.
HILO-TEST manufatcures a wide range of High Current Surge Generators for Telecom component testing applications. Generators are available for applications including:
  • Measurement of dc- and impulse spark-over voltage of gas discharge tubes (Front-Chopped-Wave generators)
  • Surge Testing of over-voltage protectors
  • Impulse Life Test generator
  • Combination Wave Testing of two-gap overvoltage protectors, as per CCITT 12 TR 1. K12
  • Surge Current Generators inc. FCC, Part 68, ANSI/TIA 968-A-2002 & GR-1089-CORE
  • Power Induction Generator for CCITT, 12 TR 1, K20
Component Testing
Advice or Questions?
.....................................................................................................................................................

If you have any questions concerning either our products or services, or simply want advice on how to best solve your particular problem, please  don't hesitate to contact us.